PEMODELAN ALIRAN UDARA PADA SISTEM DUCTING DENGAN METODE COMPUTATIONAL FLUID DYNAMICS DAN PEMILIHAN EXHAUST FAN YANG TEPAT UNTUK CLOUD KITCHEN: (TINJAUAN PERANCANGAN DI GEDUNG X KOTA TANGERANG)

Dianita Aprillia, . (2024) PEMODELAN ALIRAN UDARA PADA SISTEM DUCTING DENGAN METODE COMPUTATIONAL FLUID DYNAMICS DAN PEMILIHAN EXHAUST FAN YANG TEPAT UNTUK CLOUD KITCHEN: (TINJAUAN PERANCANGAN DI GEDUNG X KOTA TANGERANG). Skripsi thesis, Universitas Pembangunan Nasional Veteran Jakarta.

[img] Text
ABSTRAK.pdf

Download (194kB)
[img] Text
AWAL.pdf

Download (2MB)
[img] Text
BAB 1.pdf
Restricted to Repository UPNVJ Only

Download (194kB)
[img] Text
BAB 2.pdf
Restricted to Repository UPNVJ Only

Download (300kB)
[img] Text
BAB 3.pdf
Restricted to Repository UPNVJ Only

Download (328kB)
[img] Text
BAB 4.pdf
Restricted to Repository UPNVJ Only

Download (653kB)
[img] Text
BAB 5.pdf

Download (132kB)
[img] Text
DAFTAR PUSTAKA.pdf

Download (155kB)
[img] Text
DAFTAR RIWAYAT HIDUP.pdf
Restricted to Repository UPNVJ Only

Download (112kB)
[img] Text
LAMPIRAN.pdf
Restricted to Repository UPNVJ Only

Download (1MB)
[img] Text
HASIL PLAGIARISME.pdf
Restricted to Repository staff only

Download (11MB)
[img] Text
ARTIKEL KI.pdf
Restricted to Repository staff only

Download (597kB)

Abstract

A cloud kitchen is a kitchen facility used to prepare and cook food that will be delivered directly to customers through online delivery services or takeaway, as this concept does not have a dine-in area and shares space among multiple brands or restaurants. This cloud kitchen consists of several kitchen units, thus requiring good air circulation. The total volume of the 19 cloud kitchen units is 407.2775 m³ or 14,383 ft³, so to meet the standard Air Change/Hour (ACH) value for commercial kitchens, which is a minimum of 30 ACH, air exchange using a ducting system is needed at a rate of 7,191.5 ft³/m. Simulation results indicate that the air velocity distribution in the ducting ranges from 0 m/s to 78.7 m/s, the pressure distribution ranges from 3900 Pa to 11125.8 Pa, and the air temperature distribution ranges from 52.3°C to 63°C. The selected exhaust fan is a centrifugal fan from Twin City Fan, model BAFF 430, with an exhaust capacity that meets the requirements, namely 7,050 – 12,300 m³/h.

Item Type: Thesis (Skripsi)
Additional Information: [No.Panggil: 2010311003] [Pembimbing: Fahrudin] [Penguji 1: Damora Rhakasywi] [Penguji 2: Sigit Pradana]
Uncontrolled Keywords: Cloud kitchen, Ducting, CFD, Simulation, Circulation.
Subjects: T Technology > TJ Mechanical engineering and machinery
Divisions: Fakultas Teknik > Program Studi Teknik Mesin (S1)
Depositing User: DIANITA APRILLIA
Date Deposited: 08 Aug 2024 09:38
Last Modified: 08 Aug 2024 09:38
URI: http://repository.upnvj.ac.id/id/eprint/32037

Actions (login required)

View Item View Item