NABILAH HAFIZHAH PURNAWAN, . (2021) Analisis Implementasi Sistem Proteksi Kebakaran Sebagai Upaya Pencegahan Kebakaran di Fakultas Kedokteran Universitas Pembangunan Nasional Veteran Jakarta Tahun 2021. Skripsi thesis, Universitas Pembangunan Nasional Veteran Jakarta.
Text
ABSTRAK.pdf Download (187kB) |
|
Text
AWAL.pdf Download (797kB) |
|
Text
BAB 1.pdf Download (189kB) |
|
Text
BAB 2.pdf Restricted to Repository UPNVJ Only Download (465kB) |
|
Text
BAB 3.pdf Restricted to Repository UPNVJ Only Download (214kB) |
|
Text
BAB 4.pdf Restricted to Repository UPNVJ Only Download (1MB) |
|
Text
BAB 5.pdf Download (176kB) |
|
Text
DAFTAR PUSTAKA.pdf Download (249kB) |
|
Text
RIWAYAT HIDUP.pdf Restricted to Repository UPNVJ Only Download (199kB) |
|
Text
LAMPIRAN.pdf Restricted to Repository UPNVJ Only Download (2MB) |
|
Text
ARTIKEL KI.pdf Restricted to Repository staff only Download (462kB) |
Abstract
Fire is an incident of flame, either small or large, which is unwanted and uncontrollable, that can threaten lives, assets, and the environment. The Regional Disaster Management Agency (BPBD) of DKI Jakarta noted that there have been around 410 fire incidents in DKI Jakarta throughout 2019. The activities Faculty of Medicine UPN Veteran Jakarta involved modern technology related to electricity and chemicals that arouse to fire hazards. This study was to analyze the implementation of a fire protection system as an effort to prevent fire in Faculty of Medicine UPN Veteran Jakarta by comparing it with applicable standards. This study used descriptive qualitative study method. This study indicate that there were discrepancies in the application of fire protection systems in Faculty of Medicine UPN Veteran Jakarta when compared to regulations Permen PU No. 26/ PRT/M/ 2008, Permen PU No. 20/PRT/M/2009, Permenakertrans No. PER. 04/MEN/1980, SNI 03-1745-2000, SNI 03-3989-2000, SNI 03-3985-2000, SNI 03-1736-2000, SNI 03-1746-2000, SNI 03-6574-2001, and NFPA 101. The active protection system applied were only fire extinguishers. The suitability of pasive protection systems were found in building materials, building construction, and compartments. The means of saving lives fulfilled were only assembly points. There were no fire organization in the Faculty of Medicine UPN Veteran Jakarta. The average suitability level of the active protection system is 10.4%; 65% passive protection system; life saving facilities 32.63%; organizing fire 10.7%.
Item Type: | Thesis (Skripsi) |
---|---|
Additional Information: | [No.Panggil: 1710713109] [Ketua Penguji: Dyah Utari] [Penguji 1: Fathinah Ranggauni Hardy] [Pennguji 2 (Pembimbing): Fandita Tonyka Maharani] |
Uncontrolled Keywords: | Fire protection system, fire prevention, educational building |
Subjects: | R Medicine > RA Public aspects of medicine > RA0421 Public health. Hygiene. Preventive Medicine |
Divisions: | Fakultas Ilmu Kesehatan > Program Studi Kesehatan Masyarakat (S1) |
Depositing User: | Nabilah Hafizhah Purnawan |
Date Deposited: | 12 Jul 2021 03:15 |
Last Modified: | 12 Jul 2021 03:15 |