Najma Zahra, . (2026) ANALISIS PENGARUH POLUSI TERHADAP DISTRIBUSI MEDAN LISTRIK ISOLATOR KERAMIK U120B PADA SISTEM 150 KV MENGGUNAKAN SIMULASI COMSOL MULTIPHYSICS. Skripsi thesis, Universitas Pembangunan Nasional Veteran Jakarta.
|
Text
ABSTRAK.pdf Download (204kB) |
|
|
Text
AWAL.pdf Download (1MB) |
|
|
Text
BAB 1.pdf Restricted to Repository UPNVJ Only Download (313kB) |
|
|
Text
BAB 2.pdf Restricted to Repository UPNVJ Only Download (627kB) |
|
|
Text
BAB 3.pdf Restricted to Repository UPNVJ Only Download (446kB) |
|
|
Text
BAB 4.pdf Restricted to Repository UPNVJ Only Download (1MB) |
|
|
Text
BAB 5.pdf Download (233kB) |
|
|
Text
DAFTAR PUSTAKA.pdf Download (216kB) |
|
|
Text
DAFTAR RIWAYAT HIDUP.pdf Restricted to Repository UPNVJ Only Download (108kB) |
|
|
Text
LAMPIRAN.pdf Restricted to Repository UPNVJ Only Download (5MB) |
|
|
Text
HASIL PLAGIARISME.pdf Restricted to Repository staff only Download (21MB) |
|
|
Text
ARTIKEL.pdf Restricted to Repository staff only Download (516kB) |
Abstract
Pollution on the surface of transmission line insulators may cause non-uniform electric field distribution, potentially increasing the risk of Flashover. This study aims to analyze the effects of pollution distribution (Top/Bottom ratio), Equivalent Salt Deposit Density (ESDD), and pollution layer thickness on the electric field distribution of U120B ceramic insulators in a 150 kV transmission system, as well as to determine the recommended number of insulator discs based on the Specific Creepage Distance (SCD) criterion and the maximum electric field. Simulations were conducted using COMSOL Multiphysics with the Electric Currents interface under a 50 Hz Frequency Domain study. The pollution layer was modeled using the Electric Shielding approach. The results indicate that, within the adopted modeling approach, variations in ESDD and pollution layer thickness have relatively minor effects on the electric field distribution, whereas variations in the Top/Bottom ratio have a more dominant influence on the concentration of the electric field. The insulator string evaluation shows that the minimum configuration satisfying the adopted criterion is 15 discs. However, when the SCD requirement for the very heavy pollution category is also considered, a configuration of 16 discs is recommended as the final configuration in this study.
| Item Type: | Thesis (Skripsi) |
|---|---|
| Additional Information: | [No. Panggil : 2210314088] [Pembimbing 1 : Luh Krisnawati] [Pembimbing 2 : Ferdyanto] [Penguji 1 : Henry Binsar Hamonangan Sitorus] [Penguji 2 : Nur Fauziyah] |
| Uncontrolled Keywords: | COMSOL Multiphysics, Electric Field Distribution, Equivalent Salt Deposit Density (ESDD), U120B Ceramic Insulator, Top/Bottom Ratio |
| Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
| Divisions: | Fakultas Teknik > Program Studi Teknik Elektro (S1) |
| Depositing User: | NAJMA ZAHRA |
| Date Deposited: | 28 Aug 2026 03:13 |
| Last Modified: | 28 Aug 2026 03:13 |
| URI: | http://repository.upnvj.ac.id/id/eprint/52987 |
Actions (login required)
![]() |
View Item |