RANCANG BANGUN KOMPOR INDUKSI 48V DC HALF-BRIDGE SERIES-RESONANT INVERTER DENGAN FREQUENCY-TRACKING MENGGUNAKAN FAST FOURIER TRANSFORM BERBASIS ESP32

Arya Kusuma Nugraha, . (2026) RANCANG BANGUN KOMPOR INDUKSI 48V DC HALF-BRIDGE SERIES-RESONANT INVERTER DENGAN FREQUENCY-TRACKING MENGGUNAKAN FAST FOURIER TRANSFORM BERBASIS ESP32. Skripsi thesis, Universitas Pembangunan Nasional Veteran Jakarta.

[img] Text
ABSTRAK.pdf

Download (78kB)
[img] Text
AWAL.pdf

Download (890kB)
[img] Text
BAB 1.pdf
Restricted to Repository UPNVJ Only

Download (86kB)
[img] Text
BAB 2.pdf
Restricted to Repository UPNVJ Only

Download (590kB)
[img] Text
BAB 3.pdf
Restricted to Repository UPNVJ Only

Download (611kB)
[img] Text
BAB 4.pdf
Restricted to Repository UPNVJ Only

Download (1MB)
[img] Text
BAB 5.pdf

Download (78kB)
[img] Text
DAFTAR PUSTAKA.pdf

Download (88kB)
[img] Text
RIWAYAT HIDUP.pdf
Restricted to Repository UPNVJ Only

Download (17kB)
[img] Text
LAMPIRAN.pdf
Restricted to Repository UPNVJ Only

Download (2MB)
[img] Text
HASIL PLAGIARISME.pdf
Restricted to Repository staff only

Download (20MB)
[img] Text
ARTIKEL.pdf
Restricted to Repository staff only

Download (458kB)

Abstract

Variations in cookware material and diameter cause shifts in the equivalent parameters of the resonant tank in induction cookers. Operating the inverter at a fixed frequency under these conditions can reduce heating efficiency and overall system performance. This study aims to design a 48V DC induction cooker based on a Half-Bridge Series-Resonant Inverter (HB-SRI) and evaluate the application of a frequency-tracking method using the Fast Fourier Transform (FFT) algorithm on an ESP32 microcontroller. Resonant frequency estimation was performed via a one-shot procedure by analyzing the first and third harmonic components of the resonant current. Performance testing compared a non-tracking mode at a fixed frequency of 20.55 kHz with the FFT-tracking mode. The applied loads included stainless-steel and carbon-steel pans with diameters of 16 cm and 18 cm. The experimental results showed that the estimated frequencies ranged from 22.93 to 26.34 kHz with a low data spread, indicated by standard deviations of 0.13–0.71 kHz and Relative Standard Deviation values of 0.51–2.82%. The highest water-heating efficiency reached 77.05% using the 16 cm stainless-steel pan. In conclusion, the implementation of FFT-based one-shot frequency-tracking effectively adjusts the operating frequency to match load characteristics, thereby significantly improving heating efficiency and performance compared to fixed-frequency operation.

Item Type: Thesis (Skripsi)
Additional Information: [No.Panggil: 2210314011] [Pembimbing 1: Ferdyanto] [Pembimbing 2: Ni Putu Devira Ayu Martini] [Penguji 1: Henry Binsar Hamonangan Sitorus] [Penguji 2: Luh Krisnawati]
Uncontrolled Keywords: Induction Cooker, Half-Bridge Series-Resonant Inverter, Fast Fourier Transform, Frequency Tracking.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Fakultas Teknik > Program Studi Teknik Elektro (S1)