Dzulfikri Adjmal, . (2026) EVALUASI PERFORMA COAP DAN WEBSOCKET DALAM KOMUNIKASI IOT SMART HYDROPONIC FAKULTAS ILMU KOMPUTER UPNVJ. Skripsi thesis, Universitas Pembangunan Nasional Veteran Jakarta.
|
Text
ABSTRAK.pdf Download (230kB) |
|
|
Text
AWAL.pdf Download (3MB) |
|
|
Text
BAB 1.pdf Restricted to Repository UPNVJ Only Download (295kB) |
|
|
Text
BAB 2.pdf Restricted to Repository UPNVJ Only Download (507kB) |
|
|
Text
BAB 3.pdf Restricted to Repository UPNVJ Only Download (592kB) |
|
|
Text
BAB 4.pdf Restricted to Repository UPNVJ Only Download (1MB) |
|
|
Text
BAB 5.pdf Download (255kB) |
|
|
Text
DAFTAR PUSTAKA.pdf Download (242kB) |
|
|
Text
RIWAYAT HIDUP.pdf Restricted to Repository staff only Download (108kB) |
|
|
Text
LAMPIRAN.pdf Restricted to Repository UPNVJ Only Download (672kB) |
|
|
Text
HASIL PLAGIARISME.pdf Restricted to Repository staff only Download (24MB) |
|
|
Text
ARTIKEL KI.pdf Restricted to Repository staff only Download (813kB) |
Abstract
Limited agricultural land has encouraged the adoption of Internet of Things (IoT)-based hydroponic systems. However, selecting an optimal communication protocol remains a major challenge because it affects the reliability and efficiency of real-time data transmission. This study aims to design a Smart Hydroponic system architecture utilizing the Constrained Application Protocol (CoAP) and WebSocket, as well as to compare their performance based on Quality of Service (QoS) parameters, including latency , jitter, throughput, and packet loss. The proposed system employs a three-layer architecture consisting of the IoT Device, Communication Protocol, and Backend Server, and is evaluated under two testing scenarios: normal operating conditions and payload size variations of 512 byte, 1024 byte, and 2048 byte. The results show that, under normal operating conditions, CoAP achieved better performance with a latency of 269.45 ms, jitter of 238.45 ms, throughput of 0.09 kbps, and packet loss of 15.69%, whereas WebSocket recorded a latency of 996.61 ms, jitter of 1,339.93 ms, throughput of 0.31 kbps, and packet loss of 17.93%. Conversely, under payload variation testing, WebSocket demonstrated better performance for large data transmissions, while CoAP experienced communication failure at a payload size of 2048 byte, resulting in 67.79% packet loss due to payload truncation caused by the packet segmentation mechanism, which subsequently led to a parsing error on the server. Based on these findings, CoAP performs better under normal operating conditions with small payloads of less than 1 KB, whereas WebSocket demonstrates superior performance for transmitting payloads larger than 1 KB.
| Item Type: | Thesis (Skripsi) |
|---|---|
| Additional Information: | [No. Panggil: 2210511084] [Pembimbing 1: Supriyanto] [Pembimbing 2: Nurhuda Maulana] [Penguji 1: Indra Permana Solihin] [Penguji 2: Novi Trisman Hadi] |
| Uncontrolled Keywords: | CoAP, Hydroponic, IoT, QoS, WebSocket |
| Subjects: | Q Science > QA Mathematics > QA75 Electronic computers. Computer science Q Science > QA Mathematics > QA76 Computer software |
| Divisions: | Fakultas Ilmu Komputer > Program Studi Informatika (S1) |
| Depositing User: | DZULFIKRI ADJMAL |
| Date Deposited: | 28 Jul 2026 05:04 |
| Last Modified: | 31 Aug 2026 06:05 |
| URI: | http://repository.upnvj.ac.id/id/eprint/51665 |
Actions (login required)
![]() |
View Item |
