MODIFIKASI PIPA HISAP KONVENSIONAL MENGGUNAKAN PIPA SPIRAL UNTUK MENGURANGI PRESSURE DROP ALIRAN FLUIDA LUMPUR AIR DAN PASIR PADA KAPAL TSHD FREEWAY

Muhamad Afrizal, . (2025) MODIFIKASI PIPA HISAP KONVENSIONAL MENGGUNAKAN PIPA SPIRAL UNTUK MENGURANGI PRESSURE DROP ALIRAN FLUIDA LUMPUR AIR DAN PASIR PADA KAPAL TSHD FREEWAY. Skripsi thesis, Universitas Pembangunan Nasional Veteran Jakarta.

[img] Text
ABSTRAK.pdf

Download (182kB)
[img] Text
AWAL.pdf

Download (450kB)
[img] Text
BAB 1.pdf
Restricted to Repository UPNVJ Only

Download (232kB)
[img] Text
BAB 2.pdf
Restricted to Repository UPNVJ Only

Download (326kB)
[img] Text
BAB 3.pdf
Restricted to Repository UPNVJ Only

Download (498kB)
[img] Text
BAB 4.pdf
Restricted to Repository UPNVJ Only

Download (824kB)
[img] Text
BAB 5.pdf

Download (201kB)
[img] Text
DAFTAR PUSTAKA.pdf

Download (195kB)
[img] Text
RIWAYAT HIDUP.pdf
Restricted to Repository UPNVJ Only

Download (123kB)
[img] Text
LAMPIRAN.pdf
Restricted to Repository UPNVJ Only

Download (372kB)
[img] Text
HASIL PLAGIARISME.pdf
Restricted to Repository staff only

Download (5MB)
[img] Text
ARTIKEL KI.pdf
Restricted to Repository staff only

Download (369kB)

Abstract

This study aims to evaluate and optimize the suction piping system on a dredger through a comparative analysis of pressure drop between a conventional pipe and a spiral pipe. The simulation was conducted using the Computational Fluid Dynamics (CFD) method, by varying the flow velocity (0.5-2.5 m/s), the volume fraction of solids (5%, 15%, and 25%), and the pipe slope of 7°, which represents a dredging depth of 5 meters. The simulation results show that at a velocity of 0.5 m/s and a volume fraction of 5%, the pressure drop of the spiral pipe is only 30.56 Pa, lower than that of the conventional pipe which reaches 55.83 Pa. However, at a velocity of 2.5 m/s and a volume fraction of 25%, the pressure drop of the spiral pipe increases to 966.18 Pa, while that of the conventional pipe is 805.39 Pa. After adding slope, the spiral pressure drop value decreased to 676.33 Pa, indicating the positive influence of the geometric configuration. In addition, the power-law index (n) value of the spiral pipe reaches 1.63, higher than the conventional pipe with (n) 1.30, indicating dilatant fluid properties. These results indicate that the selection of pipe design and slope configuration greatly affects the flow efficiency and overall performance of the dredging system.

Item Type: Thesis (Skripsi)
Additional Information: [No.Panggil: 2110313066] [Pembimbing 1: Fajri Ashfi Rayhan] [Pembimbing 2: Amir Marasabessy] [Penguji 1: Wiwin Sulistyawati] [Penguji 2: Amir Marasabessy]
Uncontrolled Keywords: Spiral pipe, conventional pipe, non-newtonian fluid, pressure drop
Subjects: V Naval Science > V Naval Science (General)
V Naval Science > VM Naval architecture. Shipbuilding. Marine engineering
Divisions: Fakultas Teknik > Program Studi Teknik Perkapalan (S1)
Depositing User: MUHAMAD AFRIZAL
Date Deposited: 05 Aug 2025 07:41
Last Modified: 05 Aug 2025 07:41
URI: http://repository.upnvj.ac.id/id/eprint/38640

Actions (login required)