STUDI DESKRIPTIF KUALITAS FISIK UDARA DI RUMAH SAKIT X BERDASARKAN PERMENKES NO. 7 TAHUN 2019

Sandro Wijaya Manullang, . (2024) STUDI DESKRIPTIF KUALITAS FISIK UDARA DI RUMAH SAKIT X BERDASARKAN PERMENKES NO. 7 TAHUN 2019. Skripsi thesis, Universitas Pembangunan Nasional Veteran Jakarta.

[img] Text
ABSTRAK.pdf

Download (34kB)
[img] Text
AWAL.pdf

Download (465kB)
[img] Text
BAB 1.pdf
Restricted to Repository UPNVJ Only

Download (115kB)
[img] Text
BAB 2.pdf
Restricted to Repository UPNVJ Only

Download (330kB)
[img] Text
BAB 3.pdf
Restricted to Repository UPNVJ Only

Download (178kB)
[img] Text
BAB 4.pdf
Restricted to Repository UPNVJ Only

Download (254kB)
[img] Text
BAB 5.pdf

Download (90kB)
[img] Text
DAFTAR PUSTAKA.pdf

Download (105kB)
[img] Text
RIWAYAT HIDUP.pdf
Restricted to Repository UPNVJ Only

Download (104kB)
[img] Text
LAMPIRAN.pdf
Restricted to Repository UPNVJ Only

Download (1MB)
[img] Text
HASIL PLAGIARISME.pdf
Restricted to Repository staff only

Download (8MB)
[img] Text
ARTIKEL KI.pdf
Restricted to Repository staff only

Download (313kB)

Abstract

Hospitals are a high risk place for transmission of nosocomial infections through direct contact or airborne transmission. To prevent this, hospitals need to pay attention to the air quality in the hospital. This research aims to determine the air physical quality at Hospital X in accordance with Permenkes No. 7 year 2019. This research was a descriptive quantitative study with the sampling technique used is purposive sampling. A total 43 rooms with 12 different types of them were included as research objects with permission from the hospital management. Temperature, humidity and particulates (PM2.5 and PM10) data were measured directly by using a heat stress meter and a particle counter. The measurement results show that of the 43 rooms, 3 rooms (7%) met temperature quality standards, 41 rooms (95%) met humidity quality standards, none (0%) met PM2.5 quality standards, and all (100%) met PM10 quality standard. As conclusion, that the physical air quality at Hospital X is 50.5%. To improve air quality, the hospital need to monitor and maintain air conditioners and exhaust fans every 3 months, not open room doors for long periods, and insist that cleaning staff clean them evenly.

Item Type: Thesis (Skripsi)
Additional Information: [No.Panggil: 1910713061] [Pembimbing: Cahya Arbitera] [Penguji 1: Arga Buntara] [Penguji 2: Nayla Kamilia Fithri]
Uncontrolled Keywords: Indoor air quality, Physical air quality, Temperature, Humidity, Dust particles
Subjects: R Medicine > R Medicine (General)
R Medicine > RA Public aspects of medicine > RA0421 Public health. Hygiene. Preventive Medicine
Divisions: Fakultas Ilmu Kesehatan > Program Studi Kesehatan Masyarakat (S1)
Depositing User: Sandro Wijaya Manullang
Date Deposited: 29 Jan 2024 02:52
Last Modified: 13 Feb 2024 03:09
URI: http://repository.upnvj.ac.id/id/eprint/29187

Actions (login required)

View Item View Item