The Influence of Wet Scrubber on the Performance Efficiency of Heat Exchanger at Gasification Based Waste to Energy Power Plants

Regina Natalindah Lumbantoruan, . (2025) The Influence of Wet Scrubber on the Performance Efficiency of Heat Exchanger at Gasification Based Waste to Energy Power Plants. The International Journal of Marine Engineering Innovation and Research, 10 (4). pp. 1201-1208. ISSN 2548-1479

[img] Text
2210311029_ArtikelKI.pdf
Restricted to Repository staff only

Download (506kB)

Abstract

This research investigates the influence of wet scrubber installation on the performance efficiency of a shell and tube heat exchanger operating in a gasification-based Waste-to-Energy (WtE) power plant located in Surakarta, Indonesia. The study was conducted using a quantitative comparative approach over a four-month operational period, comparing system performance before and after the application of a wet scrubber. Three key parameters such as heat exchanger effectiveness, fouling factor, and pressure drop were analyzed to determine the impact of the gas cleaning system on thermal performance. The results show that the fouling factor decreased from 0.003 to 0.002 J/h·m²·°C, indicating cleaner heat transfer surfaces. Meanwhile, the pressure drop on the tube side reduced from 130.374 Pa to 46.134 Pa, reflecting smoother gas flow and lower mechanical resistance. Consequently, heat exchanger efficiency increased dramatically from 34% to 83%, signifying a substantial improvement in heat transfer capability. These findings confirm that the wet scrubber effectively minimizes tar and fine particulate deposits in syngas, improving heat transfer efficiency, operational stability, and equipment lifespan. The integration of wet scrubbers is therefore proven to be a vital enhancement for optimizing gas cleaning and energy conversion processes in Waste-to-Energy systems.

Item Type: Article
Additional Information: [No.Panggil: 2210311029] [Pembimbing 1: Damora Rhakasywi] {Pembimbing2: Fahrudin}
Uncontrolled Keywords: Heat Exchanger, Efficiency, Energy, Gasification, Pressure Drop, Fouling Factor, Thermal
Subjects: T Technology > TD Environmental technology. Sanitary engineering
T Technology > TJ Mechanical engineering and machinery
Divisions: Fakultas Teknik > Program Studi Teknik Mesin (S1)
Depositing User: REGINA NATALINDAH LUMBANTORUAN
Date Deposited: 23 Feb 2026 01:44
Last Modified: 23 Feb 2026 01:44
URI: http://repository.upnvj.ac.id/id/eprint/42230

Actions (login required)

View Item View Item