Zulfan Luto, . (2024) ANALISIS THERMAL COMFORT PADA RUANGAN KABIN PENUMPANG KELAS EKONOMI PADA KAPAL FERRY KMP. JAGANTARA. Skripsi thesis, Universitas Pembangunan Nasional Veteran Jakarta.
Text
ABSTRAK.pdf Download (19kB) |
|
Text
AWAL.pdf Download (963kB) |
|
Text
BAB 1.pdf Restricted to Repository UPNVJ Only Download (475kB) |
|
Text
BAB 2.pdf Restricted to Repository UPNVJ Only Download (882kB) |
|
Text
BAB 3.pdf Restricted to Repository UPNVJ Only Download (905kB) |
|
Text
BAB 4.pdf Restricted to Repository UPNVJ Only Download (849kB) |
|
Text
BAB 5.pdf Download (19kB) |
|
Text
DAFTAR PUSTAKA.pdf Download (147kB) |
|
Text
RIWAYAT HIDUP.pdf Restricted to Repository UPNVJ Only Download (122kB) |
|
Text
LAMPIRAN.pdf Download (838kB) |
|
Text
HASIL PLAGIARISME.pdf Download (11MB) |
|
Text
ARTIKEL KI.pdf Restricted to Repository staff only Download (266kB) |
Abstract
The passenger cabin is a critical component of passenger ships, ensuring comfort during sea voyages. This study aims to analyze thermal comfort conditions in the economy class passenger cabin of the ship KMP. JAGANTARA. Utilizing CBE Thermal comfort Tools and referencing the ASHRAE-55 standard, the research reveals that the current thermal comfort levels in the passenger cabin of KMP. JAGANTARA have not yet reached desired levels. Achieving optimal thermal comfort requires a tailored approach involving variations in passenger numbers and adjustments in room dimensions. Calculations indicate that reducing the number of passengers can decrease the cooling load within the cabin. For instance, with 144 passengers, the cooling load remains below the ideal threshold (83405 BTU < 83836 BTU). Additionally, increasing the room dimensions positively impacts thermal comfort. For example, a room measuring 325.93 m3 meets thermal comfort criteria (100.397 BTU < 101.965 BTU). then with lighting conditions of 1/4 of the total lighting, the ideal cooling load is found to be at a passenger capacity of 149 people (84775 BTU/h < 83775 BTU/h). Thus, varying passenger numbers and adjusting room dimensions represent viable strategies to enhance thermal comfort in the passenger cabin of KMP. JAGANTARA in accordance with the ASHRAE-55 standard. These measures are expected to provide valuable recommendations for improving the design and management of passenger cabins in other passenger ships
Item Type: | Thesis (Skripsi) |
---|---|
Additional Information: | [No. Panggil:2010313010] {Pembimbing 1: fajri Ashfi rayhan] [Pembimbing;Fathin Muhammad Mahdhudhu] [Penguji 1;Fakhri Akbar Ayub] [Penguji 2:Purwo Joko Suranto] |
Uncontrolled Keywords: | Thermal comfort, ASHRAE-55 Standard, cooling load. |
Subjects: | Q Science > QP Physiology T Technology > T Technology (General) V Naval Science > V Naval Science (General) |
Divisions: | Fakultas Teknik > Program Studi Teknik Perkapalan (S1) |
Depositing User: | ZULFAN LUTO |
Date Deposited: | 09 Aug 2024 08:56 |