ANALISIS PERBANDINGAN CONDUCTED EMISSION DENGAN VARIASI BEBAN LAMPU AC PADA PV OFF GRID

Dimas Pratama Wijaya, . (2024) ANALISIS PERBANDINGAN CONDUCTED EMISSION DENGAN VARIASI BEBAN LAMPU AC PADA PV OFF GRID. Skripsi thesis, Universitas Pembangunan Nasional Veteran Jakarta.

[img] Text
ABSTRAK.pdf

Download (37kB)
[img] Text
AWAL.pdf

Download (7MB)
[img] Text
BAB 1.pdf
Restricted to Repository UPNVJ Only

Download (105kB)
[img] Text
BAB 2.pdf
Restricted to Repository UPNVJ Only

Download (706kB)
[img] Text
BAB 3.pdf
Restricted to Repository UPNVJ Only

Download (295kB)
[img] Text
BAB 4.pdf
Restricted to Repository UPNVJ Only

Download (581kB)
[img] Text
BAB 5.pdf

Download (97kB)
[img] Text
DAFTAR PUSTAKA.pdf

Download (104kB)
[img] Text
RIWAYAT HIDUP.pdf
Restricted to Repository UPNVJ Only

Download (98kB)
[img] Text
LAMPIRAN.pdf
Restricted to Repository UPNVJ Only

Download (2MB)
[img] Text
HASIL PLAGIARISM.pdf
Restricted to Repository staff only

Download (11MB)
[img] Text
ARTIKEL KI.pdf
Restricted to Repository staff only

Download (583kB)

Abstract

Conducted Emissions are generated through conductive pathways, such as cables and power lines. Conducted Emissions can be caused by various factors such as switching operations, harmonics, or other electrical disturbances. It is important to control the emissions carried out, so that the electron device functions properly and meets electromagnetic compability (EMC) standards. Some ways to reduce conducted emissions are to apply proper grounding techniques to minimize interference signals, using filters to attenuate interference signals. Line Impedance Stabilization Network (LISN) is a device commonly used to measure electromagnetic interference (EMI) generated by electronic devices. Researchers use this LISN to be able to take data when measurements have been made. The author in this case uses a research object in the form of an Off-Grid PV system with load variations to obtain the population in this study. Like lamps with power variations with various brands. The researcher took samples with power variations in the lamps with each of 5 different brands. As you can see, there are also blue and yellow lines that indicate the limit that can be called CISPR 15 for lighting qualifications. In this regard, CISPR (Comité International Spécial des Perturbations Radioélectriques) to establish standards for controlling electromagnetic interference in electrical and electronic devices. It was found in this study, there were several experiments, namely comparing different brands with regular wattage, such as 5 watts, 7 watts, and 9 watts. Another thing that is done is by giving parallel and series series loads. Where when parallel series and series series, the same brand with different wattages compared to Conducted Emission is more aggressive through the load with its own lights or parallel circuits.

Item Type: Thesis (Skripsi)
Additional Information: [No.Panggil: 2010314053] [Pembimbing: Henry Binsar Hamonangan Sitorus] [Penguji 1: Luh Krisnawati] [Penguji 2: Silvia Anggraeni]
Uncontrolled Keywords: Conducted Emission; Lamp AC; PV Off Grid
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Fakultas Teknik > Program Studi Teknik Elektro (S1)
Depositing User: DIMAS PRATAMA WIJAYA
Date Deposited: 06 Aug 2024 03:41
Last Modified: 06 Aug 2024 03:41
URI: http://repository.upnvj.ac.id/id/eprint/31748

Actions (login required)