ANALISIS INSTALASI KELISTRIKAN DENGAN STANDAR PUIL 2011 PADA GEDUNG FAKULTAS TEKNIK UPNVJ UNTUK MENINGKATKAN KUALITAS DAN KEANDALAN INFRASTRUKTUR KELISTRIKAN BANGUNAN

Augusta Erlangga, . (2024) ANALISIS INSTALASI KELISTRIKAN DENGAN STANDAR PUIL 2011 PADA GEDUNG FAKULTAS TEKNIK UPNVJ UNTUK MENINGKATKAN KUALITAS DAN KEANDALAN INFRASTRUKTUR KELISTRIKAN BANGUNAN. Skripsi thesis, Universitas Pembangunan Nasional Veteran Jakarta.

[img] Text
ABSTRAK.pdf

Download (422kB)
[img] Text
AWAL.pdf

Download (1MB)
[img] Text
BAB 1.pdf
Restricted to Repository UPNVJ Only

Download (674kB)
[img] Text
BAB 2.pdf
Restricted to Repository UPNVJ Only

Download (1MB)
[img] Text
BAB 3.pdf
Restricted to Repository UPNVJ Only

Download (1MB)
[img] Text
BAB 4.pdf
Restricted to Repository UPNVJ Only

Download (1MB)
[img] Text
BAB 5.pdf

Download (557kB)
[img] Text
DAFTAR PUSTAKA.pdf

Download (434kB)
[img] Text
RIWAYAT HIDUP.pdf
Restricted to Repository UPNVJ Only

Download (301kB)
[img] Text
LAMPIRAN.pdf
Restricted to Repository UPNVJ Only

Download (10MB)
[img] Text
HASIL PLAGIARISME.pdf
Restricted to Repository staff only

Download (21MB)
[img] Text
ARTIKEL KI.pdf
Restricted to Repository staff only

Download (430kB)

Abstract

Electricity is crucial for commercial and industrial buildings with high energy demands. As population, economic, and quality of life improve, energy consumption in buildings significantly increases. To ensure safety and operational efficiency, good regulatory standards for electrical and lighting installations are essential. This study aims to analyze the feasibility and compliance of the electrical and lighting systems in the Faculty of Engineering building at UPN “Veteran” Jakarta with the General Requirements for Electrical Installations (PUIL) 2011 and the Indonesian National Standard (SNI) 03-6575-2001. The research methods employed include literature review, observation, interviews, direct measurements, design simulations, and data analysis. Based on the findings, the electrical system, according to PUIL 2011, exhibits discrepancies such as 55.10% of cables not meeting color standards, 5.56% not meeting size standards, 92.36% of circuit breakers not meeting load capacity standards, 40% of circuit breakers failing short-circuit current specifications, and the voltage drop is still within the limits allowed by the standard, which is a maximum of 5% for low voltage systems (230/400 V). Adjustments to these standards are necessary to mitigate the risks of electrical disturbances and accidents. Regarding the lighting system, based on SNI 03-6575-2001, approximately 79.41% of rooms do not meet light intensity standards, 85.29% do not comply after simulation processes, and 91.18% fail to meet standards for the number and luminosity of lamps. Improvements in distribution, quantity, types, and lamp specifications are required to achieve optimal and efficient lighting according to standards.

Item Type: Thesis (Skripsi)
Additional Information: [No.Panggil: 2010314058] [Pembimbing: Ferdyanto] [Penguji 1: Henry Binsar Hamonangan Sitorus] [Penguji 2: Achmad Zuchriadi P.]
Uncontrolled Keywords: Electrical system, lighting, PUIL 2011, SNI 03-6575-2001
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Fakultas Teknik > Program Studi Teknik Elektro (S1)
Depositing User: AUGUSTA ERLANGGA
Date Deposited: 30 Jul 2024 02:55
Last Modified: 30 Jul 2024 02:55
URI: http://repository.upnvj.ac.id/id/eprint/31592