Alya Diah Ullhaque, . (2024) ANALISIS INDOOR AIR QUALITY TERHADAP GEJALA SICK BUILDING SYNDROME PADA PEKERJA DI PT X TAHUN 2023. Skripsi thesis, Universitas Pembangunan Nasional Veteran Jakarta.
Text
ABSTRAK.pdf Download (17kB) |
|
Text
AWAL.pdf Download (535kB) |
|
Text
BAB 1.pdf Restricted to Repository UPNVJ Only Download (156kB) |
|
Text
BAB 2.pdf Restricted to Repository UPNVJ Only Download (322kB) |
|
Text
BAB 3.pdf Restricted to Repository UPNVJ Only Download (653kB) |
|
Text
BAB 4.pdf Restricted to Repository UPNVJ Only Download (449kB) |
|
Text
BAB 5.pdf Download (28kB) |
|
Text
DAFTAR PUSTAKA.pdf Download (299kB) |
|
Text
RIWAYAT HIDUP.pdf Restricted to Repository UPNVJ Only Download (297kB) |
|
Text
LAMPIRAN.pdf Restricted to Repository UPNVJ Only Download (4MB) |
|
Text
HASIL PLAGIARISME.pdf Restricted to Repository staff only Download (10MB) |
|
Text
ARTIKEL KI.pdf Restricted to Repository staff only Download (503kB) |
Abstract
Poor indoor air quality can harm human health. A closed indoor work environment and an inadequate ventilation system can increase the risk of sick building syndrome symptoms. This study aims to analyze the most significant risk factors with symptoms of sick building syndrome in workers at PT X. The study used a cross-sectional study design and the data was processed with the chi-square test and multiple logistic regression tests with a sample of all production area workers at PT X. A total of 91 workers included in this study. Carbon monoxide, temperature, humidity, PM10 and formaldehyde were measured using a particle counter and wind speed was measured using an anemometer. Measurements were taken at 17 different points. The results showed that 85 out of 91 workers (93.4%) experienced symptoms of sick building syndrome. There is a relationship between temperature (p-value=0.013) and wind speed (p-value=0.031) symptoms of sick building syndrome. The most dominant variable is the formaldehyde (POR=0.457). It is concluded that the variables associated with symptoms of sick building syndrome are temperature and wind speed, with formaldehyde being the most dominant. The company is advised to monitor indoor air quality regularly and improve the ventilation system at the production area.
Item Type: | Thesis (Skripsi) |
---|---|
Additional Information: | [No. Panggil: 2010713024] [Pembimbing: Dyah Utari] [Penguji 1: Nayla Kamilia Fithri] [Penguji 2: Arga Buntara] |
Uncontrolled Keywords: | Indoor air quality, Sick building syndrome, Workers |
Subjects: | R Medicine > R Medicine (General) R Medicine > RA Public aspects of medicine R Medicine > RA Public aspects of medicine > RA0421 Public health. Hygiene. Preventive Medicine |
Divisions: | Fakultas Ilmu Kesehatan > Program Studi Kesehatan Masyarakat (S1) |
Depositing User: | Alya Diah Ullhaque |
Date Deposited: | 26 Jan 2024 01:01 |
Last Modified: | 23 Feb 2024 06:17 |
URI: | http://repository.upnvj.ac.id/id/eprint/29090 |
Actions (login required)
View Item |