Yolanda Siahaan, . (2023) ANALISIS KINERJA WATER COOLED CHILLER MENGGUNAKAN FLUIDA R-134A PADA GEDUNG X. Skripsi thesis, Universitas Pembangunan Nasional Veteran Jakarta.
Text
ABSTRAK.pdf Download (18kB) |
|
Text
AWAL.pdf Download (578kB) |
|
Text
BAB 1.pdf Download (300kB) |
|
Text
BAB 2.pdf Restricted to Repository UPNVJ Only Download (1MB) |
|
Text
BAB 3.pdf Restricted to Repository UPNVJ Only Download (1MB) |
|
Text
BAB 4.pdf Restricted to Repository UPNVJ Only Download (1MB) |
|
Text
BAB 5.pdf Download (159kB) |
|
Text
DAFTAR PUSTAKA.pdf Download (384kB) |
|
Text
RIWAYAT HIDUP.pdf Restricted to Repository UPNVJ Only Download (19kB) |
|
Text
LAMPIRAN.pdf Restricted to Repository UPNVJ Only Download (1MB) |
|
Text
HASIL PLAGIARISME.pdf Restricted to Repository staff only Download (12MB) |
|
Text
ARTIKEL KI.pdf Restricted to Repository staff only Download (761kB) |
Abstract
Indonesia as a country with a tropical climate, is in dire need of an air conditioning system that is useful for creating thermal comfort for occupants and the production process of industrial equipment in a building, using a different method, namely cold water as the source. The HVAC system is a cooling system that is used to control temperature, humidity and air pressure to be lower than the ambient temperature to achieve the desired conditions. Water cooled chiller is a refrigeration machine that uses cold water as an indirect cooling system. The first step in planning the HVAC system is to calculate the cooling load in the building's room to find out whether the capacity of the chiller cooling system can handle the cooling load or not. In this study, the calculation of the cooling load using the CLTD (Cooling Load Temperature Difference) method. From the results of calculating the cooling load in building X, it shows an average total cooling load of 10.312.346,16 Btu/hr which is mostly generated from the internal load of the equipment, with a chiller capacity of 6.002.981,42 Btu/hr, and with the performance of the water cooled chiller in efficient conditions with an average COP value of 9,09.
Item Type: | Thesis (Skripsi) |
---|---|
Additional Information: | [No.Panggil: 1810311028] [Pembimbing: Damora Rhakasywi] [Penguji 1: Fahrudin] [Penguji 2: Fitri Wahyuni] |
Uncontrolled Keywords: | Water cooled chiller, Cooling load, Chiller capacity, Air conditioning system |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) T Technology > TH Building construction T Technology > TJ Mechanical engineering and machinery |
Divisions: | Fakultas Teknik > Program Studi Teknik Mesin (S1) |
Depositing User: | Yolanda Siahaan |
Date Deposited: | 03 Aug 2023 11:23 |
Last Modified: | 03 Aug 2023 11:23 |
URI: | http://repository.upnvj.ac.id/id/eprint/25406 |