ANALISIS PENGARUH VARIASI BEBAN TURBIN GAS TERHADAP EFISIENSI HEAT RECOVERY STEAM GENERATOR TIPE TRIPLE PRESSURE REHEAT UNIT 4.2 PLTGU X

Reza Arnanda, . (2022) ANALISIS PENGARUH VARIASI BEBAN TURBIN GAS TERHADAP EFISIENSI HEAT RECOVERY STEAM GENERATOR TIPE TRIPLE PRESSURE REHEAT UNIT 4.2 PLTGU X. Skripsi thesis, Universitas Pembangunan Nasional Veteran Jakarta.

[img] Text
ABSTRAK.pdf

Download (11kB)
[img] Text
AWAL.pdf

Download (527kB)
[img] Text
BAB 1.pdf

Download (102kB)
[img] Text
BAB 2.pdf
Restricted to Repository UPNVJ Only

Download (1MB)
[img] Text
BAB 3.pdf
Restricted to Repository UPNVJ Only

Download (517kB)
[img] Text
BAB 4.pdf
Restricted to Repository UPNVJ Only

Download (791kB)
[img] Text
BAB 5.pdf

Download (78kB)
[img] Text
DAFTAR PUSTAKA.pdf

Download (149kB)
[img] Text
RIWAYAT HIDUP.pdf
Restricted to Repository UPNVJ Only

Download (86kB)
[img] Text
LAMPIRAN.pdf
Restricted to Repository UPNVJ Only

Download (269kB)
[img] Text
HASIL PLAGIARISME.pdf
Restricted to Repository staff only

Download (17MB)
[img] Text
ARTIKEL KI.pdf
Restricted to Repository staff only

Download (741kB)

Abstract

Electricity needs are always changing because it is influenced by consumer demand. The changing demand for electrical energy consumption must be followed by the amount and availability of loads generated by the generator. PLTGU X often experiences load changes where these changes will affect the performance of other components, especially HRSG. HRSG is a tool to produce steam by utilizing the heat of exhaust gas from PLTG. Calculations using HRSG Unit 4.2 operational data on January 18, 2022 using load variations between 205 MW to 250 MW. The calculation process is carried out in theory and simulation using Cycle Tempo Release 5.0. From the calculation results, it is found that the variation of the gas turbine load can affect the performance of the HRSG. HRSG's energy efficiency decreases when it reaches high loads. Energy efficiency has increased from a load of 210 MW and then a downward trend occurs at a load of 220 MW to 250 MW. The HRSG's exergy efficiency also increases as the gas turbine load increases. The exergy efficiency of the steam turbine increases with the increase in the HRSG inlet gas temperature. Efficiency has an increasing trend from 594°C to 612.13°C. The temperature of the HRSG inlet gas affects the efficiency of the steam power cycle which increases with the increase in the temperature of the exhaust gas entering the HRSG. The heat transfer rate increases as the gas turbine load increases. The heat transfer rate increased from a load of 205 MW of 3702535 kJ/s to 250 MW of 4232602,069 kJ/s

Item Type: Thesis (Skripsi)
Additional Information: [No.Panggil: 1810311064] [Pembimbing: Damora Rhakasywi] [Penguji 1: James Julian] [Penguji 2: Fayza Yulia]
Uncontrolled Keywords: HRSG, Efisiensi Energi, Efisiensi Eksergi, Heat Transfer Rate
Subjects: T Technology > TJ Mechanical engineering and machinery
Divisions: Fakultas Teknik > Program Studi Teknik Mesin (S1)
Depositing User: Reza Arnanda
Date Deposited: 25 Jul 2022 03:18
Last Modified: 26 Jul 2022 05:32
URI: http://repository.upnvj.ac.id/id/eprint/18565

Actions (login required)